Framing and Structural Components is about 20% of the CSLB General Building (B) exam. CSLB's B study guide splits it into five subtopics: subfloor and wall framing, roof framing, seismic hardware requirements and installation, siding and stucco, and decks and stairs. Almost every rule comes from the 2025 California Residential Code (CRC): Chapter 3 for decay protection, fireblocking, stairs and guards, Chapter 4 for foundations and anchor bolts, Chapter 5 for floors and decks, Chapter 6 for walls and bracing, Chapter 7 for siding and stucco, and Chapter 8 for roofs. Cal/OSHA's Title 8 adds the fall protection heights for framing crews.
This note covers the numbers each subtopic is built on, with the section each one comes from. The CRC states many of these rules in tables; the numbers below are in our own words, and you should read the table itself for the cases we leave out.
Subfloor and wall framing
Lumber and decay protection
- Actual sizes (common building practice): a 2x4 is 1 1/2 by 3 1/2 inches, a 2x6 is 1 1/2 by 5 1/2, a 2x10 is 9 1/4 inches deep and a 2x12 is 11 1/4 inches deep.
- Crawl space clearances. Wood must be naturally durable or preservative-treated where it is closer to exposed ground than 18 inches for joists, 12 inches for girders and 8 inches for columns. Framing on an exterior foundation wall less than 8 inches from exposed ground also needs it. (2025 CRC §R304.1)
- Crawl space vents and access. Vents give 1 square foot for each 150 square feet of under-floor area, one within 3 feet of each corner, with mesh openings no larger than 1/4 inch; a Class I vapor retarder on the ground drops the ratio to 1/1,500 (2025 CRC §R408.2). Access is 18 by 24 inches through the floor or 16 by 24 inches through a wall (2025 CRC §R408.4).
- Sill plate. At least a nominal 2x4 on a foundation wall. (2025 CRC §R404.3)
A girder 13 inches above the ground may be untreated, but joists 16 inches above the ground must be treated or naturally durable.
Floor framing
- Bearing. Joists, beams and girders bear at least 1 1/2 inches on wood or metal and 3 inches on masonry or concrete. (2025 CRC §R502.6)
- Laps. Joists from opposite sides lap at least 3 inches over a support, nailed with three 10d face nails. (2025 CRC §R502.6.1)
- Bearing partitions running across joists are offset no more than the joist depth from the support. (2025 CRC §R502.4)
- Openings. A header spanning 4 feet or less may be single; over 4 feet, header and trimmers are doubled. (2025 CRC §R502.10)
- Span tables. Sleeping rooms use a 30 psf live load; other rooms use 40 psf. (2025 CRC §R502.3.1, §R502.3.2)
- Notches and holes in sawn joists: notches up to 1/6 of the depth, never in the middle third of the span, 1/4 at the ends; holes up to 1/3 of the depth and 2 inches from the edges. A 2x12 may take a 1 7/8-inch notch away from the ends and a 3 3/4-inch hole. (2025 CRC §R502.8.1)
- Subfloor nailing: 6 inches on center at panel edges and 12 inches in the field. (2025 CRC Table R602.3(1))
Wall framing
- Studs. A 2x4 bearing stud up to 10 feet tall may be 24 inches on center under a roof only, and 16 inches when it also carries one floor; a 2x6 at 16 inches may carry two floors and a roof. (2025 CRC §R602.3.1)
- Top plates. End joints in a double top plate are offset at least 24 inches. With a single top plate, rafters and joists sit within 1 inch of the studs below. (2025 CRC §R602.3.2)
- Stud notches and holes. A notch may take 25% of the width in an exterior or bearing wall and 40% in a nonbearing wall. A hole may take 60%, with its edge at least 5/8 inch from the stud edge; in an exterior or bearing wall, a hole over 40% means doubling the stud. A 2 1/2-inch hole in a 2x6 is 45%, so the stud is doubled. (2025 CRC §R602.6)
- Cut top plate. A plate cut more than half its width gets a 16-gage steel tie, 1 1/2 inches wide, with eight 10d nails on each side, extending 6 inches past the opening. (2025 CRC §R602.6.1)
- Headers. The header table assumes the top of the header is braced; where cripple studs bear on it, multiply 2x8, 2x10 and 2x12 spans by 0.70. (2025 CRC §R602.7) King studs are set by opening width and wind speed: a 10-foot opening at 130 mph, Exposure B, needs 3 king studs at each end (2025 CRC §R602.7.5).
- Cripple walls over 4 feet tall get studs sized as an added story. (2025 CRC §R602.9)
Fireblocking and moisture
- Fireblocking goes at the floor and ceiling and every 10 feet horizontally in stud walls. Accepted materials include 2-inch nominal lumber, two layers of 1-inch lumber, 23/32-inch wood structural panel, 3/4-inch particleboard and 1/2-inch gypsum board. Unfaced fiberglass must fill the cavity 16 inches high. (2025 CRC §R302.11)
- Draftstopping limits concealed floor-ceiling areas to 1,000 square feet, with 1/2-inch gypsum board or 3/8-inch wood structural panel. (2025 CRC §R302.12)
- Moisture. Framing is not enclosed above 19% moisture content. (2025 CALGreen §4.505.3)
Roof framing
- Rafter length is the long side of a right triangle. On a 5:12 roof with a 12-foot run, the rise is 5 feet and the rafter is √(144 + 25) = 13 feet before overhang (common building practice).
- Ridge, hips and valleys. A ridge board is at least 1 inch nominal and as deep as the rafter's cut end. Hip and valley rafters are at least 2 inches nominal. Below a 3:12 pitch, the ridge, hips and valleys are designed as beams. (2025 CRC §R802.3, §R802.4)
- Collar ties are at least 1x4, in the upper third of the attic, no more than 4 feet on center. (2025 CRC §R802.4.6)
- Ceiling joists and rafter ties that tie the walls together go in the bottom third of the rafter height. Rafter ties are at least 2x4 and no more than 24 inches on center. (2025 CRC §R802.5.2)
- Purlins are braced with 2x4s at no less than 45 degrees, no more than 4 feet on center. (2025 CRC §R802.4.5)
- Roof openings. Header single up to 4 feet, doubled with trimmers over 4 feet, and on hangers over 6 feet. A 5-foot skylight opening needs doubled members but no hangers. (2025 CRC §R802.9)
- Trusses may not be cut, notched or altered without approval of a registered design professional, and are braced per the truss design drawings. (2025 CRC §R802.10)
- Attic ventilation. Net free vent area is 1/150 of the vented space; 1/300 only when both conditions in the code are met. An 1,800-square-foot attic needs 12 square feet. Vent openings are 1/16 to 1/4 inch. (2025 CRC §R806)
- Attic access. Needed where an attic has 30 inches or more of height over at least 30 square feet; the rough opening is at least 22 by 30 inches, with 30 inches of headroom above a ceiling opening. (2025 CRC §R807.1)
Fall protection. Setting trusses and sheathing a house roof is residential-type framing: fall protection at 6 feet or more since July 1, 2025 (8 CCR §1716.2). The 15-foot rule for walking on trusses, beams or plates 4 inches or wider applies elsewhere, where guardrails are impracticable (8 CCR §1669).
Seismic hardware requirements and installation
Anchor bolts and plate washers
- Anchor bolts are at least 1/2 inch in diameter, embedded 7 inches, no more than 6 feet apart, in the middle third of the plate. Each plate section has at least two bolts, with one within 12 inches of each end and no closer than 7 bolt diameters. (2025 CRC §R403.1.6)
- Short walls. A connecting wall 24 inches or shorter needs one bolt in its center third; a wall 12 inches or shorter may skip it. (2025 CRC §R403.1.6)
- More than two stories in SDC D0 to D2: bolts at 4 feet on center. (2025 CRC §R403.1.6.1)
- Plate washers in SDC D0 to D2 are at least 0.229 by 3 by 3 inches. (2025 CRC §R602.11.1)
Wall bracing
- Braced wall lines are spaced up to 25 feet apart in SDC D0 to D2 (35 feet for one room up to 900 square feet), and 60 feet where wind governs. (2025 CRC §R602.10.1.3)
- Panel location. A braced wall panel begins within 10 feet of each end of the line, with no more than 20 feet between panel edges. (2025 CRC §R602.10.2.2)
- Methods. Wood structural panel (WSP) sheathing is at least 3/8 inch, nailed 6 inches at edges and 12 inches in the field. Gypsum board (GB) bracing is 1/2 inch, fastened 7 inches on center. In SDC C, D0, D1 and D2, bracing sheathing, gypsum board included, may not be attached with adhesive. (2025 CRC §R602.10.4)
- Minimum panel length for most methods: 48 inches on 8- to 10-foot walls. Let-in bracing needs 55, 62 or 69 inches on 8-, 9- or 10-foot walls. (2025 CRC §R602.10.5)
- Cripple walls take the same bracing method as the wall above, with the length multiplied by 1.15: 16 feet of bracing above becomes 18.4 feet below. If no segment along the line is taller than 48 inches, the cripple walls may be braced as a first story; one taller segment makes the whole cripple wall an added story. (2025 CRC §R602.10.10)
Other hardware
- Water heater straps go in the upper third and lower third, with the lower strap at least 4 inches above the controls. (2025 CPC §507.2)
- Deck lateral hold-downs: two devices of 1,500 pounds within 24 inches of each end of the deck, or four of 750 pounds. (2025 CRC §R507.9.2)
- Masonry veneer ties support no more than 2.67 square feet of wall each (2 square feet in SDC D0 to D2), spaced no more than 32 inches across and 24 inches up. (2025 CRC §R703.8.4.1)
Siding and stucco
- Clearances. The foundation extends at least 6 inches above finished grade, 4 inches with masonry veneer (2025 CRC §R404.1.6). Untreated siding and sheathing stay 6 inches from the ground and 2 inches above exposed slabs (2025 CRC §R304.1).
- Water-resistive barrier. No. 15 felt laps 2 inches at horizontal joints and 6 inches at vertical joints. (2025 CRC §R703.2)
- Laps. Wood lap siding laps 1 inch (1/2 inch if rabbeted) (2025 CRC §R703.5.3); fiber-cement lap siding laps 1 1/4 inches (2025 CRC §R703.10.2).
- Vinyl siding stays 6 inches from the ground and 1/2 inch from decks, roofs and slabs. (2025 CRC §R703.3.1)
Stucco (exterior cement plaster)
| Rule | Number | Source |
|---|---|---|
| Lath nails | 1 1/2 inches, 11 gage, 7/16-inch head, every 7 inches along framing | 2025 CRC §R703.7.1 |
| Coats | 3 over metal or wire lath; 2 over masonry or concrete | 2025 CRC §R703.7.2 |
| Thickness over wire lath | 7/8 inch | 2025 CRC Table R702.1(1) |
| Weep screed | 0.019 inch (No. 26 gage), 3 1/2-inch flange, 4 inches above earth, 2 inches above paving | 2025 CRC §R703.7.2.1 |
| Moist curing of each coat | 48 hours before the next | 2025 CRC §R703.7.4 |
| Finish coat, three-coat work | 7 days after the second coat | 2025 CRC §R703.7.5 |
| Barrier in dry climates | Two layers of Grade D paper, or one 60-minute layer with a separation layer | 2025 CRC §R703.7.3.1 |
A scratch coat applied at 8 a.m. Monday allows the brown coat at 8 a.m. Wednesday and the finish coat 7 days later, 9 days after the scratch coat. (2025 CRC §R703.7.5)
- Adhered veneer stays 4 inches above earth, 2 inches above paving and 1/2 inch above a walking surface on the same foundation. (2025 CRC §R703.12.1)
Decks and stairs
Decks
- Permit exemption: see the 4 conditions in the Planning and Estimating note; an attached deck always needs a permit (2025 CRC §R105.2).
- Footings are at least 12 inches below undisturbed ground (2025 CRC §R507.3.2). Joists and beams bear 1 1/2 inches on wood or metal and 3 inches on concrete (2025 CRC §R507.5.1, §R507.6.1).
- Lumber and fasteners. Deck lumber is No. 2 or better (2025 CRC §R507.2.1). Without maker data, connectors such as joist hangers in treated wood are at least G185 galvanized steel (2025 CRC §R304.3.1). Within 300 feet of a salt water shoreline, deck fasteners and connectors are stainless steel (2025 CRC §R507.2.3).
- Joist spans come from the deck joist table: at 40 psf, a No. 2 Douglas fir-larch 2x8 at 16 inches on center spans 11 feet 1 inch. (2025 CRC §R507.6)
- Ledger. At least a 2x8, attached with bolts or lag screws, never with toenails or nails in withdrawal, and never to stone or masonry veneer. Flashing goes up the wall at least 2 inches. (2025 CRC §R507.9.1)
Guards and stairs
| Rule | Number | Source |
|---|---|---|
| Guard required | Walking surface more than 30 inches above the grade within 36 inches of the edge | 2025 CRC §R321.1.1 |
| Guard height | 42 inches; 34 inches on the open side of stairs | 2025 CRC §R321.1.2 |
| Guard openings | No 4-inch sphere; 4 3/8 inches on the open side of stairs | 2025 CRC §R321.1.3 |
| Stair width | 36 inches | 2025 CRC §R318.7.1 |
| Headroom | 6 feet 8 inches | 2025 CRC §R318.7.2 |
| Riser height | 7 3/4 inches maximum; 3/8 inch variation | 2025 CRC §R318.7.5.1 |
| Tread depth | 10 inches minimum | 2025 CRC §R318.7.5.2 |
| Nosing | 3/4 to 1 1/4 inches, not needed with 11-inch treads | 2025 CRC §R318.7.5.3 |
| Handrail required | 4 or more risers | 2025 CRC §R318.7.8 |
| Handrail height | 34 to 38 inches | 2025 CRC §R320.2 |
| Landing at an exterior door | 36 inches deep, as wide as the door | 2025 CRC §R318.3 |
Laying out a stair. A floor-to-floor rise of 105 inches ÷ 7.75 = 13.55, so the stair needs 14 risers of 7 1/2 inches; 13 would be 8.08 inches. Fourteen risers mean 13 treads; at 10 1/2 inches each, the run is 136 1/2 inches. Risers of 7 5/8 and 7 1/8 inches in one flight fail: each is under 7 3/4, but they differ by more than 3/8 inch. (2025 CRC §R318.7.5.1)
On the job. Temporary job stairs follow Title 8: rails 34 to 38 inches, and a variation of no more than 1/4 inch. (8 CCR §1626)
Traps to watch for
- Old numbers. Older books (2022 CRC) put stairs in R311 and guards in R312. In the 2025 CRC, stairways are R318.7, handrails R320 and guards R321.
- Which fraction? 1/6 is the joist notch away from the ends, 1/4 at the ends, 1/3 for holes. Studs use 25%, 40% and 60%.
- Upper or lower third? Collar ties go high; ceiling joists and rafter ties that resist thrust go in the bottom third of the rafter height.
- 6 inches or 2 inches? Untreated wood siding clears the ground by 6 inches and an exposed slab by 2 inches; a weep screed clears earth by 4 inches and paving by 2.
- Guard height. House deck guards in California are 42 inches, not 36. The 34-inch figure is only for the open side of a stair.
- Riser count. Divide the total rise by 7 3/4 and round up; there is one fewer tread than risers.
For answered practice questions on this section, start with subfloor and wall framing, roof framing, seismic hardware, siding and stucco and decks and stairs. The guides on California stair and guard rules and deck requirements go deeper on the last subtopic. Fall protection for framing crews is covered in the Safety notes and the fall protection guide.