Section 1: Planning and Estimating

RuleNumberSource
Scope of work and code compliance
Shed exempt from a building permit (one story, detached)Floor area not over 120 square feet
Retaining wall exempt from a building permitOnly if it supports no surcharge. Under the CBC it also must not impound Class I, II or IIIA liquids.Not over 4 feet, measured from the bottom of the footing to the top of the wall
Permit expires when work has not startedFor permits issued on or after January 1, 2019.12 months after the permit is issued
Design and construction error identification
Notch in a sawn floor joist (not at the ends)Not in the middle third of the span. Notches at the ends may be up to 1/4 of the depth.Depth not more than 1/6 of the joist depth; length not more than 1/3 of the depth
Bored hole in a sawn floor joistAt least 2 inches from the top or bottom edge, from other holes and from notches.Diameter not more than 1/3 of the joist depth
Ceiling height in habitable space and hallwaysAt least 7 feet
Shop drawings, plans, and specifications
Hallway width in a dwellingAt least 3 feet (36 inches)
Habitable room floor areaKitchens are exempt.At least 70 square feet
Habitable room horizontal dimensionKitchens are exempt.At least 7 feet in any direction
Field inspection performance
Moisture content of wall and floor framing before it is enclosedNot over 19%
Water test of drain, waste and vent pipingAt least a 10-foot head of water, held 15 minutes before the inspection
Fireblocking in concealed wall spaces, horizontal intervalNot more than 10 feet
Coordination of project
Written notice to adjoining owners before an excavationAt least 10 days before the excavation
Nonhazardous construction and demolition waste recycled or salvagedAt least 65%
Indoor humidity range in the CALGreen operation and maintenance manual30% to 60% relative humidity

Section 2: Framing and Structural Components

RuleNumberSource
Subfloor and wall framing
Bearing length at the ends of joists, beams and girdersAt least 1 1/2 inches on wood or metal; at least 3 inches on masonry or concrete
Notch in a wall studUp to 25% of the stud depth in exterior or bearing walls; up to 40% in nonbearing walls
Bored hole in a wall studOver 40% in an exterior or bearing wall: double the stud, with no more than 2 doubled studs in a row.Up to 60% of the stud depth, at least 5/8 inch from the edge
Roof framing
Ridge board sizeAt least 1 inch nominal thickness, and as deep as the cut end of the rafter
Rafter ties used in place of ceiling joistsAt least 2x4, at most 24 inches on center
Attic access openingRequired where the attic area is more than 30 square feet and 30 inches or more high.At least 22 by 30 inches, with at least 30 inches of headroom above
Seismic hardware requirements and installation
Sill plate anchor boltsEach bolt sits in the middle third of the plate width.1/2-inch diameter, at most 6 feet on center, embedded at least 7 inches
Braced wall panel offset from its braced wall lineNo more than 2/3 of the required bracing length may sit on one side of the line.Up to 4 feet
Braced wall panel location along a braced wall lineFirst panel within 10 feet of each end; at most 20 feet between the edges of adjacent panels
Siding and stucco
Wood siding, sheathing and wall framing that must be treated or naturally durableCloser than 6 inches to the ground, or closer than 2 inches above an exposed slab or step
Number of exterior cement plaster (stucco) coats3 coats over metal or wire lath; 2 coats over masonry, concrete, treated wood or gypsum backing
Timing of three-coat stuccoSecond coat at least 48 hours after the first; finish coat at least 7 days after the second
Decks and stairs
When a guard is requiredWalking surface more than 30 inches above the floor or grade below, at any point within 36 inches of the edge
Guard height34 to 38 inches where the guard also serves as the handrail.At least 42 inches; at least 34 inches on the open side of a stair
Openings in a guardNo 4-inch sphere passes; 4 3/8 inches on the open side of a stair; 6 inches at the stair triangle
Stair riser height in a dwellingRisers may slope up to 30 degrees from vertical. Open risers: no 4-inch sphere passes where the total rise is more than 30 inches.At most 7 3/4 inches, varying no more than 3/8 inch in a flight
Stair tread depth in a dwellingAt least 10 inches, varying no more than 3/8 inch in a flight

Section 3: Core Trades

RuleNumberSource
Plumbing
Minimum slope of horizontal drainage piping1/4 inch per foot (2 percent)
Fixture trap sealAt least 2 inches and not more than 4 inches
Vent pipe termination above the roofAt least 6 inches above the roof, and at least 1 foot from a vertical surface
Electrical
Dwelling wall receptacle spacingApplies to wall spaces 2 feet or wider; floor receptacles count only within 18 inches of the wall.No point along the floor line more than 6 feet from a receptacle
Overcurrent protection for small conductors14 AWG copper 15 amps; 12 AWG copper 20 amps; 10 AWG copper 30 amps; 12 AWG aluminum 15 amps; 10 AWG aluminum 25 amps
Clearance from overhead power lines of 600 to 50,000 volts6 feet in general; 10 feet for booms and stored materials
HVAC
Maximum length of a domestic clothes dryer exhaust ductUnless the dryer maker allows a longer duct.14 feet with two 90-degree elbows; subtract 2 feet for each extra elbow
Insulation on ducts in unconditioned spaceR-4.2 is allowed in a qualifying unvented attic (R-30 at the roof deck and 3.0 ACH50 or less).At least R-6.0
Air filter on a forced-air system with more than 10 feet of ductworkMERV 13 or better
Concrete
Minimum concrete strength for house foundations and slabs (at 28 days)2,500 psi; 3,000 psi for walls exposed to moderate or severe weathering and for porches and garage floors in moderate regions; 3,500 psi for porches and garage floors in severe regions
Minimum concrete footing size for a houseThe footing may project no less than 2 inches and no more than its thickness past the face of the wall.12 inches wide by 6 inches thick
Concrete slab-on-ground thicknessAt least 3 1/2 inches
Earthwork and surveying
Notice to 811 before diggingThe day of the call does not count.At least 2 working days, and not more than 14 calendar days, before the work
Cave-in protection system requiredShallower ones need it too unless a competent person finds no sign of a possible cave-in; not needed in stable rock.Excavations 5 feet deep or more
Ladder or other way out of a trenchRequired in trenches 4 feet or more deep, within 25 feet of lateral travel
Insulation, acoustical, and weatherproofing
Mandatory framed-wall insulation, new homesNonframed walls: U-0.102.2x4: U-0.095 (R-15); 2x6: U-0.069 (R-21 at 16 inches on center)
Mandatory raised-floor insulation, new homesU-0.037 or R-19
Net free vent area of an enclosed attic1/300 only when both of the code's conditions are met.1/150 of the vented space
Roofing
Fasteners per asphalt shingleAbove 21:12, follow the maker's instructions.At least 4 per strip shingle; at least 2 per individual shingle
Base (step) flashing where a shingle roof meets a sidewallAt least 4 inches high by 4 inches wide
Cricket or saddle required on the ridge sideChimney or roof penetration more than 30 inches wide

Section 4: Finish Trades

RuleNumberSource
Painting, staining, coating, and interior wall covering
VOC limit, flat coatings50 grams per liter
VOC limit, nonflat coatings100 grams per liter
Cal/OSHA permissible exposure limit for lead in constructionIn effect since January 1, 2025.10 micrograms per cubic meter, 8-hour average
Tile and stone
Nonabsorbent wall finish at showers and tubs with showers (homes)At least 6 feet above the floor
Finished shower curb (dam) height compared with the sides and back of the receptorAt least 1 inch lower
VOC limit, ceramic tile adhesive65 grams per liter
Floor covering
Particleboard floor underlaymentType PBU, at least 1/4 inch thick
Change in level on an accessible route, left verticalUp to 1/4 inch
Change in level on an accessible route, beveledOver 1/4 inch up to 1/2 inch, beveled no steeper than 1:2
Cabinetry and millwork
Formaldehyde limit, particleboard0.09 parts per million
Unobstructed reach range, forward or side (public buildings)High reach at most 48 inches; low reach at least 15 inches above the floor
Force to operate an accessible control, latch or handleUsable with one hand, without tight grasping, pinching or twisting of the wrist.At most 5 pounds
Plaster, drywall, and ceilings
Fastener spacing, 1/2- or 5/8-inch gypsum board on walls with framing 16 inches on centerWithout adhesive.Nails 8 inches on center; screws 16 inches on center
Garage ceiling where any part of the dwelling is aboveAt least 5/8-inch Type X gypsum board
Enclosed accessible space under a stairAt least 1/2-inch gypsum board on the walls, the underside of the stair and the soffits
Windows, skylights, and doors
Emergency escape and rescue opening, net clear areaAt least 5.7 square feet; 5 square feet at a grade floor
Emergency escape and rescue opening, net clear sizeAt least 24 inches high and 20 inches wide
Emergency escape and rescue opening, sill heightAt most 44 inches above the floor to the bottom of the clear opening
Safety glazing next to tubs, showers, hot tubs and poolsNot required where the glass is more than 60 inches, measured horizontally, from the water's edge.Required where the bottom edge of the glass is less than 60 inches above the standing surface
Landscaping
Model Water Efficient Landscape Ordinance applies to a new landscapeApplies when the project needs a building or landscape permit, plan check or design review.Landscape area of 500 square feet or more
Model Water Efficient Landscape Ordinance applies to a rehabilitated landscapeApplies when the project needs a building or landscape permit, plan check or design review.Landscape area of 2,500 square feet or more
Mulch on exposed soil in planting areasNot required in turf, creeping or rooting groundcovers, or direct seeding where mulch is contraindicated. Up to 5% of the landscape area may stay unmulched as insect habitat if shown on the plan.At least 3 inches deep

Section 5: Safety

RuleNumberSource
Personnel safety
Toolbox (tailgate) safety meetingsHeld by supervisors with their crews, or an equivalent meeting.At least every 10 working days
Report a serious injury or death to Cal/OSHA24 hours if the employer can show exigent circumstances.Within 8 hours
Fall protection, residential-type roofingRoofs 0:12 through 7:12. Steeper than 7:12: at any height. In effect since July 1, 2025.6 feet or more
Fall protection, general construction (edges, perimeters, openings, shafts)Falls of more than 7 1/2 feet
Job-site guardrailA parapet at least 21 inches high may take the place of the midrail.Top rail 42 to 45 inches high, withstands 200 pounds and stays at least 39 inches high under that load; midrail withstands 150 pounds
Transportation and traffic control
Merging taper length (W = offset width in feet, S = speed in mph)W × S² ÷ 60 at 40 mph or less; W × S at 45 mph or more
Distance from the first advance warning sign to the work, urban streetsAbout 4 to 8 times the speed limit, in feet
Height to the bottom of a roadside work zone sign1 foot on portable supports.7 feet in urban areas and where people park or walk; 5 feet in rural areas
Aggregate load hauled uncovered on a highwayOtherwise the load must be covered. Loads made up entirely of asphalt are exempt from the covering rule only.At least 6 inches below the upper edge where the load touches the sides, front and back, with the peak no higher than the upper edge
Environmental safety
Construction Stormwater General Permit coverage neededDisturbing 1 acre or more, or part of a common plan of development of 1 acre or more
Lead-safe work area covering (renovation rule)Outdoors, close doors and windows within 20 feet of the work.At least 6 feet beyond the work indoors; at least 10 feet outdoors
Lead renovation recordsGive the owner the compliance information at the final invoice or within 30 days of completion, whichever is earlier.Kept for 3 years after the job

Test yourself

Try 25 free General Building practice questions from all five sections. Each answer explains the rule and names the code section it comes from. No sign-up.

See what the General Building exam covers