Skip to content
CalContractorPrep
Menu

What's on the CSLB General Building (B) Exam: 5 Sections, Weights and Format

About the B exam

Updated

The CSLB General Building (B) exam has 5 sections and 28 subtopics. The biggest section is Core Trades at about 30%; Planning and Estimating and Safety are the smallest at about 15% each. These weights come from CSLB's own General Building study guide (form 13E-B, dated 03-2026, for exams scheduled on or after January 1, 2025), which says the percentages are approximate.

This page walks through the sections, the format of the questions and the books CSLB lists, then suggests a study order based on the weights. The facts below link to the CSLB page or code section they come from; the study order at the end is our own suggestion.

The 5 sections and their weights

# Section Weight Subtopics
1 Planning and Estimating 15% 6
2 Framing and Structural Components 20% 5
3 Core Trades 30% 7
4 Finish Trades 20% 7
5 Safety 15% 3
Total 100% 28

CSLB marks these percentages as approximate and does not publish the number of questions, so a percentage cannot be turned into an exact question count. Use the weights to decide where your study time goes.

Two things stand out:

  • Core Trades alone is about 30% of the exam, as much as Planning and Estimating and Safety together. It covers seven trades, from plumbing and electrical to roofing.
  • Framing and Finish Trades are about 20% each. With Core Trades, the three trade sections are about 70% of the exam.

The 28 subtopics, section by section

The subtopic names below are the ones in the study guide.

1. Planning and Estimating (15%)

  • Scope of work and code compliance
  • Design and construction error identification
  • Shop drawings, plans, and specifications
  • Field inspection performance
  • Coordination of project
  • Cost estimation for materials, equipment, and labor

This section is about reading the job before you build it: what the code requires, what the plans show, when inspections happen, and what the work will cost. Cost estimation means quantity takeoffs, such as the cubic yards of concrete in a slab. Example rule: a hallway in a dwelling must be at least 3 feet wide (2025 CRC §R318.6).

2. Framing and Structural Components (20%)

  • Subfloor and wall framing
  • Roof framing
  • Seismic hardware requirements and installation
  • Siding and stucco
  • Decks and stairs

The structure of a house and its skin: floor and wall framing, rafters and trusses, hold-downs and other seismic hardware, siding and stucco, and decks and stairs.

3. Core Trades (30%)

  • Plumbing
  • Electrical
  • HVAC
  • Concrete
  • Earthwork and surveying
  • Insulation, acoustical, and weatherproofing
  • Roofing

The largest section, covering the trades a general building contractor coordinates and the rules each one works to. The 2025 California Electrical Code is based on the 2023 National Electrical Code.

4. Finish Trades (20%)

  • Painting, staining, coating, and interior wall covering
  • Tile and stone
  • Floor covering
  • Cabinetry and millwork
  • Plaster, drywall, and ceilings
  • Windows, skylights, and doors
  • Landscaping

The work that finishes a building. Several of these topics are as much about materials, methods and quantities (how many tiles cover a floor) as about code sections.

5. Safety (15%)

  • Personnel safety
  • Transportation and traffic control
  • Environmental safety

Cal/OSHA's job site rules, traffic control on public roads, and environmental rules such as stormwater. Example rule: in general construction, workers exposed to a fall of more than 7 1/2 feet from an unprotected edge need fall protection (8 CCR §1670). Study notes: Safety.

How the questions work

The study guide describes the format:

  • Closed book. No reference materials may be used during the exam.
  • Four choices per question, written so that only one is the BEST answer.
  • Some questions require math. A calculator is provided.
  • No penalty for guessing. CSLB says it is better to answer a question than to leave it blank.
  • Plenty of time. CSLB advises reading each question and all four choices completely before choosing.
  • Questions are written and reviewed by licensed contractors who are actively working in the trade.

CSLB's page on what happens after your exam application is accepted adds the practical details:

  • You have 3 1/2 hours to complete each examination.
  • The exam is taken on a computer-assisted testing system at a PSI test center. No computer experience is needed.
  • Pencils, scratch paper, calculators and scale rulers are provided at the test center on request. Personal calculators, phones and other electronic devices are not allowed in the testing area.
  • You get your result before you leave. If you pass, you are told only that you passed. If you do not, you get a statement of how you did in each section, matching the sections in the study guide.
  • After a failed exam you must wait 21 calendar days to pay and reschedule. You have 18 months from the date your application is accepted to pass.
  • Exam results are good for five years: if you pass the trade exam but not the Law and Business exam, you retake only the one you failed, within five years.

What the math looks like

The study guide's sample questions include a volume problem, and estimating questions use the same arithmetic. Two examples:

  • Cylinder volume. A cylinder 3 feet across and 12 feet long: the radius is 1.5 feet, so the volume is 3.14 × 1.5 × 1.5 × 12 = 84.78 cubic feet. This is one of CSLB's own sample questions.
  • Concrete for a slab. A slab 36 feet by 27 feet and 4 inches thick: 36 × 27 × 1/3 = 324 cubic feet, and 324 ÷ 27 = 12 cubic yards before waste.

CSLB's three sample questions

The study guide includes three sample questions:

  1. What is the minimum width of a residential hallway under the California Residential Code? Answer: 36 inches.
  2. What is the volume of a cylinder 3 feet in diameter and 12 feet long? Answer: 84.78 cubic feet.
  3. What is the most likely cause of a severe crack in a foundation? Answer: inadequate soil preparation.

The 2025 codes, and a numbering trap

The study guide lists the 2025 California codes in Title 24. They took effect on January 1, 2026. The state's Building Standards Commission links to free online versions of each code from its codes page, so you can read any section a question is built on.

The 2025 California Residential Code renumbered many sections of Chapter 3. Older books and practice tests may send you to the wrong rule:

Topic 2025 CRC section
Means of egress: doors, hallways, stairs, ramps R318 (hallways R318.6, stairways R318.7)
Emergency escape and rescue openings R319
Handrails R320
Guards R321
Safety glazing R324
Fire sprinklers R309
Smoke alarms R310
Carbon monoxide alarms R311

If a source says stairs are in R311, it is using the old numbering; in the 2025 code, R311 is carbon monoxide alarms.

The reference list

The study guide lists these references. You do not need to read them cover to cover; use them to look up the rules behind questions you miss.

  • The 2025 California codes (Title 24): Building Code, Residential Code, Electrical Code, Energy Code, Fire Code, Green Building Standards Code (CALGreen), Mechanical Code and Plumbing Code.
  • Cal/OSHA safety orders (Title 8): the General Industry, Construction and Electrical Safety Orders. They are free on the Department of Industrial Relations site.
  • California Manual on Uniform Traffic Control Devices from Caltrans. The study guide names the 2014 edition, Revision 4; Caltrans' current manual is the 2026 edition.
  • California Vehicle Code.
  • North American Architectural Woodwork Standards.
  • Fundamentals of Building Construction: Materials and Methods (Wiley), Modern Carpentry (Goodheart-Willcox) and Olin's Construction Principles, Materials, and Methods (Wiley).

CSLB also publishes the study guide in Spanish.

A study order by weight

This is our suggested plan, not a CSLB requirement. It starts with the heaviest section and leaves time for mixed review.

Week Sections Combined weight
1 3 Core Trades 30%
2 2 Framing and Structural Components, 4 Finish Trades 40%
3 1 Planning and Estimating, 5 Safety, then mixed review 30%

Tips for using it:

  • Read, then practice. Read a section's notes, then answer practice questions on it the same day.
  • Track misses by section. A failing result is reported by section, so practice the same way.
  • Do the math by hand once. A calculator is provided, but you still need to know which numbers to multiply.
  • Study without your books open. The exam is closed book.
  • Check the edition. Use the 2025 codes and current Cal/OSHA numbers. Several heights and limits changed in 2025.

Applicants usually take CSLB's Law and Business exam too. See our Law and Business exam outline for that one.

Practice questions

Think of your answer first, then open the explanation.

  1. 1. Under the California Residential Code, the minimum width of a hallway in a dwelling is:

    Planning and Estimating

    • A. 30 inches
    • B. 36 inches
    • C. 42 inches
    • D. 48 inches
    Show answer

    Correct answer: B

    • A. 30 inches

      Wrong: narrower than the 3-foot minimum.

    • B. 36 inches

      Correct answer

      Correct: R318.6 requires 3 feet.

    • C. 42 inches

      Wrong: wider than the minimum; not the code figure.

    • D. 48 inches

      Wrong: wider than the minimum; not the code figure.

    Explanation

    California Residential Code section R318.6 requires a hallway to be at least 3 feet (36 inches) wide.

  2. 2. A new house has a gas fireplace inside the primary bedroom. The plans show carbon monoxide alarms in the hallway outside the sleeping area and on every occupiable level. Under the California Residential Code, what is missing?

    Planning and Estimating

    • A. A carbon monoxide alarm inside every bedroom in the house
    • B. A carbon monoxide alarm in the garage
    • C. Nothing; the hallway alarm covers the bedroom
    • D. A carbon monoxide alarm inside the primary bedroom
    Show answer

    Correct answer: D

    • A. A carbon monoxide alarm inside every bedroom in the house

      Wrong: only the bedroom with the fuel-burning appliance needs its own alarm.

    • B. A carbon monoxide alarm in the garage

      Wrong: R311.3 does not call for an alarm in the garage.

    • C. Nothing; the hallway alarm covers the bedroom

      Wrong: a fuel-burning appliance in a bedroom requires an alarm in that bedroom.

    • D. A carbon monoxide alarm inside the primary bedroom

      Correct answer

      Correct: R311.3 requires an alarm inside a bedroom that contains a fuel-burning appliance.

    Explanation

    California Residential Code section R311.3 places carbon monoxide alarms outside each separate sleeping area in the immediate vicinity of the bedrooms and on every occupiable level, including basements. Where a fuel-burning appliance is located inside a bedroom or its attached bathroom, an alarm is also required inside that bedroom.

  3. 3. A concrete slab is 36 feet by 27 feet and 4 inches thick. How many cubic yards of concrete does it take, before waste?

    Planning and Estimating

    • A. 12 cubic yards
    • B. 24 cubic yards
    • C. 36 cubic yards
    • D. 108 cubic yards
    Show answer

    Correct answer: A

    • A. 12 cubic yards

      Correct answer

      Correct: 324 cu ft / 27 = 12 cu yd.

    • B. 24 cubic yards

      Wrong: uses 8 inches of thickness instead of 4.

    • C. 36 cubic yards

      Wrong: divides by 108 instead of converting to feet and dividing by 27.

    • D. 108 cubic yards

      Wrong: 108 is the area in square yards (972 / 9), not a volume.

    Explanation

    Area = 36 ft x 27 ft = 972 sq ft. Thickness = 4 in / 12 = 1/3 ft. Volume = 972 x 1/3 = 324 cu ft. 324 / 27 cu ft per cubic yard = 12 cubic yards.

    Common building practice; not a code requirement.

  4. 4. Workers are installing ductwork near the unprotected edge of a mezzanine in a commercial building. This is not roofing work or residential-type framing. Under Cal/OSHA section 1670, fall protection is required when the fall distance is more than:

    Safety

    • A. 4 feet
    • B. 6 feet
    • C. 7 1/2 feet
    • D. 15 feet
    Show answer

    Correct answer: C

    • A. 4 feet

      Wrong: not the trigger in section 1670.

    • B. 6 feet

      Wrong: 6 feet is the trigger for residential-type framing and roofing, not this work.

    • C. 7 1/2 feet

      Correct answer

      Correct: more than 7 1/2 feet (section 1670(a)).

    • D. 15 feet

      Wrong: 15 feet is not the trigger in section 1670; the rule uses a fall of more than 7 1/2 feet.

    Explanation

    Title 8 section 1670(a) requires workers exposed to a fall of more than 7 1/2 feet from unprotected sides and edges to use an approved personal fall arrest, fall restraint or positioning system when not otherwise protected. Roofing and residential-type framing follow their own sections.

    Source

Test yourself

Try 25 free General Building practice questions from all five sections. Each answer explains the rule and names the code section it comes from. No sign-up.

See what the General Building exam covers