The 2025 California Residential Code (CRC), in force since January 1, 2026, renumbered most of Chapter 3. Means of egress, including stairways, is now R318 (stairways R318.7); handrails have their own section, R320; guards are R321; safety glazing is R324; fire sprinklers are R309; smoke alarms are R310; and carbon monoxide alarms are R311 (2025 CRC Chapter 3). A book or practice test that puts stairs in R311 or guards in R312 is using the older numbering.
This page gives the old-to-new table for the sections the General Building (B) exam leans on, a map of what sits where in the 2025 Chapter 3, the moves in other chapters that matter on a job, and a few other 2025 changes that catch people using older material. CSLB's B study guide lists the 2025 codes, so the 2025 numbers are the ones to learn.
The sections that moved
| Topic | 2025 CRC | Number in the 2022 edition and older books |
|---|---|---|
| Means of egress: egress door, landings, hallways, stairways, ramps | R318 (door R318.2, landings R318.3, hallways R318.6, stairways R318.7, ramps R318.8) | R311 in the 2022 edition |
| Emergency escape and rescue openings | R319 | R310 in the 2022 edition |
| Handrail height, clearance and grip | R320 | R311.7.8 in the 2022 edition |
| Guards and window fall protection | R321 | R312 in the 2022 edition |
| Safety glazing (and skylights, R324.6) | R324 | R308 in the 2022 edition |
| Automatic fire sprinklers | R309 | R313 in the 2022 edition |
| Smoke alarms | R310 | R314 in the 2022 edition |
| Carbon monoxide alarms | R311 | R315 in the 2022 edition |
The new numbers are not just shifted by one or two. In the 2025 code, R311 is carbon monoxide alarms, R312 is minimum room areas and R313 is ceiling height, so an old citation lands on a real but different rule. That is why a wrong number is a trap and not just a typo.
One rule to remember at each new number
Learn each new number with one rule that lives there:
- R318.6 hallways: at least 3 feet wide (2025 CRC §R318.6).
- R318.7 stairways: risers at most 7 3/4 inches, treads at least 10 inches, and a single flight rises no more than 12 feet 7 inches between floors or landings (2025 CRC §R318.7.3).
- R319 escape openings: every sleeping room needs one (2025 CRC §R319.1); the opening is at least 20 inches wide and 24 inches high (2025 CRC §R319.2.2), with at least 5.7 square feet of net clear area, or 5 square feet at a grade floor (2025 CRC §R319.2.1), and a sill no more than 44 inches above the floor (2025 CRC §R319.2.3).
- R320 handrails: 34 to 38 inches high (2025 CRC §R320.2), with at least 1 1/2 inches of space from the wall (2025 CRC §R320.4). R318.7.8 still says when a stair needs a handrail (4 or more risers) (2025 CRC §R318.7.8); the handrail details are all in R320.
- R321 guards: at least 42 inches high in California, 34 inches on the open side of a stair (2025 CRC §R321.1.2).
- R324 glazing: glass next to a tub or shower is a hazardous location when its bottom edge is less than 60 inches above the standing surface (2025 CRC §R324.4.5).
- R309 sprinklers: required in new one- and two-family dwellings, designed to R309 or NFPA 13D; additions and alterations to an unsprinklered building, and some detached accessory dwelling units, are excepted (2025 CRC §R309.2).
- R310 smoke alarms: at least 3 feet horizontally from the door of a bathroom with a tub or shower, where there is room (2025 CRC §R310.3).
- R311 carbon monoxide alarms: required where the home has a fuel-fired appliance or fireplace, or an attached garage with an opening into the home (2025 CRC §R311.2.1); where more than one alarm is required, they must be interconnected (2025 CRC §R311.5).
- R312 room areas: a habitable room other than a kitchen has at least 70 square feet (2025 CRC §R312.1) and is at least 7 feet in any horizontal dimension (2025 CRC §R312.2).
- R313 ceiling height: at least 7 feet in habitable rooms and hallways (2025 CRC §R313.1).
- R327 bath and shower spaces: shower compartment walls get a nonabsorbent finish at least 6 feet above the floor (2025 CRC §R327.2).
- R304 decay protection: untreated floor joists stay at least 18 inches, and girders 12 inches, above exposed ground in a crawl space (2025 CRC §R304.1).
What sits where in the 2025 Chapter 3
The 2025 Chapter 3 headings, as published (2025 CRC Chapter 3):
| 2025 section | Subject |
|---|---|
| R300 | Site drainage (California) |
| R302 | Fire-resistant construction, garage separation, fireblocking and draftstopping |
| R303 | Foam plastic |
| R304 | Protection of wood against decay |
| R305 | Subterranean termites |
| R306 | Flood-resistant construction |
| R307 | Storm shelters |
| R308 | Site address |
| R309 | Automatic fire sprinkler systems |
| R310 | Smoke alarms |
| R311 | Carbon monoxide alarms |
| R312 | Minimum room areas |
| R313 | Ceiling height |
| R314 | Mezzanines |
| R315 | Sleeping lofts |
| R316 | Habitable attics |
| R317 | Garages and carports |
| R318 | Means of egress |
| R319 | Emergency escape and rescue openings |
| R320 | Handrails |
| R321 | Guards and window fall protection |
| R322 | Accessibility |
| R323 | Elevators and platform lifts |
| R324 | Glazing, including skylights |
| R325 | Light, ventilation and heating |
| R326 | Sanitation |
| R327 | Toilet, bath and shower spaces |
| R328 | Aging-in-place design and fall prevention (California) |
| R329 | Solar energy systems |
| R330 | Energy storage systems |
| R334 | Construction waste (California) |
| R337 | A pointer to the California Wildland-Urban Interface Code |
R302 kept its number, so garage separation and fireblocking are where they were.
Wildfire rules left the CRC
R337 is now only a pointer. The materials and methods for wildfire exposure are in Title 24, Part 7, the California Wildland-Urban Interface Code (2025 CRC §R337). Roofing in a Fire Hazard Severity Zone or Wildland-Urban Interface area also meets Part 7 (2025 CRC §R902.1.1).
Numbers to check in other chapters
The 2025 text was read for these sections; check your notes against them.
- Slabs-on-ground (Chapter 5). R506.2 is now post-tensioned slabs. Site preparation, fill, base and the vapor retarder are under R506.3, with the vapor retarder at R506.3.3 (2025 CRC §R506.3.3) and California's capillary break pointer at R506.3.3.1.
- Floors. R502.11 is now floor framing that supports guards; floor trusses, draftstopping and fireblocking follow at R502.12 to R502.14 (2025 CRC Chapter 5).
- Decks. Ledger flashing has its own section, R507.9.1.5 (2025 CRC §R507.9.1.5).
- Reroofing (Chapter 9). Tear-off to the deck is R908.3 (2025 CRC §R908.3); recover, and the three cases where it is not allowed, is R908.4 (2025 CRC §R908.4); recover over wood shingles or shakes is R908.4.1. Chapter 9 cites R324.6 for unit skylights and R329 for rooftop solar.
- Exterior walls (Chapter 7). Stucco is R703.7, anchored masonry veneer R703.8 and adhered masonry veneer R703.12 (2025 CRC §R703.8).
The 2025 text itself still has a few stale cross-references. R317.5.1 refers to "Section R313" for sprinklers, a leftover older number (sprinklers are R309). R702.1 sends interior masonry veneer to stucco sections, and the bracing table's stucco entry points to R703.6, which is wood shakes and shingles. Follow the subject, not the stale number.
Other 2025 changes that catch people
These are not CRC sections, but older books show other numbers:
- Plumbing Code shower sections. The 2025 California Plumbing Code's own relocation table moves the finished curb or threshold to 408.6 and shower compartments to 408.7, one number higher than the previous edition (2025 CPC §408.7).
- Electrical. The 2025 California Electrical Code is the 2023 NEC (NFPA 70) with California amendments, and it keeps the NEC section numbers (NFPA 70, 2023).
- Fall protection. Residential-type framing and roofing need fall protection at 6 feet or more since July 1, 2025; residential roofs steeper than 7:12 need it at any height (8 CCR §1716.2, §1731).
- Lead. The construction lead PEL is 10 µg/m³, with an action level of 2, since January 1, 2025 (8 CCR §1532.1).
- PPE fit. Since October 1, 2025, PPE must be selected to properly fit each worker (8 CCR §1514).
How to use this page
- Rewrite your notes. Cross out every 2022 number in your flash cards and write the 2025 number beside it.
- Learn number and rule together. "R321, 42 inches" sticks better than either alone.
- Watch for a wrong number in an answer choice. If a choice cites R311 for stairs, it is using the older numbering.
- Use the free code viewer. The Building Standards Commission links to each 2025 code from its codes page.
For the stair and guard numbers in detail, see our stair and guard guide. For the whole exam, start with the B exam outline.